Chiller Repair Myths Busted: What Facility Leaders Really Need to Know Before a Breakdown

06/25/2026

Download

If you’ve managed commercial HVAC equipment long enough, you’ve probably heard some interesting maintenance advice.

“Just reset the alarm.”

“Spray the condenser coils with a sprinkler.”

“If it’s still running, it’s fine.”

Some of these myths have been passed around for years. Others come from good intentions. Unfortunately, many can lead to reduced efficiency, unnecessary repairs, or even equipment failure.

Our technicians encounter these misconceptions regularly in the field. Here are a few of the most common myths they hear, and what actually keeps chillers operating reliably.

MYTH 1: 

If the Chiller Is Running, Everything Is Fine

One of the most expensive assumptions in facility management is believing that operating equipment = healthy equipment.

In reality, many systems that appear to be ‘working’ are running 20-30% longer cycles to meet demand. Chiller-specific issues like internal tube fouling, refrigerant imbalances, or early-stage compressor wear don’t cause immediate shutdowns. Instead, they silently destroy efficiency. For example, even a thin layer of scale inside heat exchanger tubes acts as an insulator, forcing the compressor to run longer and harder to achieve the same cooling load. This not only inflates energy bills but also accelerates wear on the system’s most expensive components.

The facilities that experience fewer emergencies aren’t necessarily the ones with newer equipment. They’re the ones that investigate problems while they’re still small.

REALITY:

Waiting for equipment to fail usually results in more downtime, more expensive repairs, and greater disruption to your facility.

MYTH 2:

Spraying water on condenser coils helps the chiller run cooler.

This is one of the more common suggestions technicians hear during the Oklahoma summer.

While spraying water may seem like a quick way to improve performance, it often creates new problems.

Minerals left behind from hard water can build up on condenser coils, trapping dirt and reducing heat transfer over time. What seems like a temporary fix can actually decrease efficiency and increase maintenance costs.

REALITY:

Clean coils improve performance. Sprinklers don’t.

MYTH 3: 

Cleaning Coils Is Just Spraying Them Off…Simple

Cleaning condenser coils isn’t just about removing dirt.

Using the wrong cleaner, excessive water pressure, or cleaning against the direction of airflow can damage coil fins or leave debris deeper inside the coil, where it continues restricting airflow.

According to the U.S. Department of Energy, dirty coils can significantly increase energy consumption and reduce system efficiency, making coil cleaning one of the highest-return maintenance activities available.

Proper cleaning techniques help restore efficiency without damaging the equipment.

REALITY:

How you clean the coils matters just as much as how often you clean them.

MYTH 4: 

Air Filters Work the Same No Matter Which Direction They’re Installed

You’d be surprised how often our technicians encounter this one.

Every air filter is designed to operate with airflow moving in a specific direction. That’s why manufacturers place airflow arrows directly on the filter frame.

Improper filter installation restricts airflow, reduces efficiency, and can contribute to higher operating temperatures throughout the system.

It’s a simple detail that can create much larger problems over time. Sometimes the simplest issues have the biggest impact.

REALITY:

Small installation mistakes can have a big impact on system performance.

MYTH 5: 

“A Chiller Is A Chiller.  They all need the same maintenance”

This is a dangerous oversimplification. The maintenance needs of an air-cooled chiller and a water-cooled chiller are fundamentally different.

While an air-cooled unit relies on cleaning condenser fins to reject heat, a water-cooled system depends on a cooling tower and requires regular water treatment to prevent scale, corrosion, and biological growth.

Neglecting water treatment can lead to fouled condenser tubes, severely restricted heat transfer, and even expensive acid cleanings. A generic maintenance plan that ignores these differences leads to critical under-servicing of one system or the other.

MYTH 6: 

All Test Equipment Is Accurate Right Out of the Box

When troubleshooting electrical issues, the quality and accuracy of your testing equipment matter more than many people realize.

Not every meter or testing tool is built to the same standard. While online marketplaces can be convenient, they can also make it difficult to know exactly where a tool came from or whether it meets the manufacturer’s specifications. Counterfeit or poorly calibrated tools do exist, and inaccurate readings can lead to incorrect diagnoses, unnecessary part replacements, or even unsafe working conditions.

Whenever possible, purchase testing equipment from a trusted electrical supply house or reputable distributor. No matter where your tools come from, inspect and verify they are functioning properly before relying on the readings they provide.

A low-quality or inaccurate instrument can send a technician chasing problems that don’t exist while overlooking the ones that do.

That’s why professional technicians routinely verify their instruments before making critical diagnostic decisions. If the data is wrong, every decision that follows may be wrong too.

REALITY:

Good troubleshooting starts with good data. If you can’t trust your test equipment, you can’t trust your diagnosis.

MYTH 7: 

“I Can Tell If a Wire Is Live Without a Meter”

Our technicians still hear stories about electrical troubleshooting methods that belong in the past.

Besides being dangerous, they’re unreliable.

Modern chillers and HVAC systems contain sophisticated controls, sensors, safety devices, and electrical components that require proper testing equipment.

When it comes to electrical troubleshooting, guessing is never a maintenance strategy.

Proper lockout/tagout procedures and calibrated testing equipment exist for a reason.

Safety should never be based on assumptions.

REALITY:

Electricity doesn’t reward experience. It rewards safe, proven procedures.  Good technicians don’t guess. They verify.

MYTH 8: 

It’s just another nuisance alarm. Reset it and move on.

This may be the most expensive myth of all.

When an alarm appears, it’s easy to think the alarm itself is the problem.

In reality, the alarm is often doing exactly what it was designed to do.

It’s warning you that something else needs attention.

Repeatedly resetting alarms without investigating the cause doesn’t solve the problem. It simply delays it. Sometimes that delay allows a relatively minor issue to become a major repair.

REALITY:

An alarm isn’t the repair. It’s the clue.

Here’s a recent example from one of our technicians below:

BONUS MYTH: 

A Repair is Cheaper Than A Replacement or A Retrofit 

Is it though?  Ask yourself, how many of those same “repairs” have you had done on that same unit in the last 1-3 years?   While it can be tempting to approve another repair on an aging chiller, there’s a tipping point where it’s no longer the smart financial decision.  

If your chiller is over 15 years old and requires frequent, expensive repairs, it’s probably time to evaluate a replacement, a retrofit, or at least have a discussion about future planning. A simple rule of thumb is to compare the repair cost against the value of a new unit. If a single repair costs more than 50% of a replacement, it’s rarely a sound investment.

Furthermore, an older unit’s energy consumption can be significantly higher than a new high-efficiency model or at minimum, retrofitting components with newer versions can also be a great option.

A Chiller Annual Energy calculating discussion with our team can help quantify the long-term ROI of a new unit, often revealing that energy savings alone can offset the initial investment over a few years.  Whatever the outcome may be from the assessment, you can rest assured that we will present you with all of your options and help you determine what is BEST for your facility (short-term & long-term).  Not what is the most expensive.

Real Troubleshooting in the Field – A Case Study

One of our technicians recently responded to a manufacturing facility after two different alarms appeared on separate chillers. One unit was reporting a low suction pressure fault, while another had experienced a complete circuit lockout.

It would have been easy to reset the alarms and hope they didn’t return.

Instead, he treated the alarms for what they were: clues.

As the troubleshooting process began, it quickly became clear that the two alarms had completely different causes.

The low suction pressure fault pointed to a refrigeration circuit that was critically low on refrigerant…a far more serious issue than a simple ‘top-off.’ In a commercial chiller, a significant leak places immense strain on the compressor as it works harder to compensate. This can lead to overheating, oil breakdown, and ultimately, catastrophic mechanical failure. Our technician added 25 pounds of R-410A to stabilize the system and immediately conducted a full electronic leak detection service. This step is critical, as simply refilling the system without fixing the leak is not a proper fix for a problem that could destroy a six-figure component. 

The circuit lockout told a very different story.

Further investigation revealed significant electrical damage inside the control panel, including evidence of a fire that had damaged critical electrical components. The lockout wasn’t an inconvenience to work around. It was a safety feature doing exactly what it was designed to do by preventing further damage and alerting the technician that a much more serious problem existed.

Neither alarm was the problem.

Each one pointed to a completely different issue that required a completely different solution.

Had either alarm simply been reset without investigating the cause, both chillers would have continued operating with underlying problems that could have resulted in additional equipment damage, unexpected downtime, or unsafe operating conditions.

That’s what good troubleshooting looks like. It’s not about clearing alarms. It’s about understanding why they happened in the first place.

Want to see how the diagnosis unfolded? Watch our technician explain the service call and the steps he took to identify the root cause in the video below.

Before Calling for Service:  A Simple Chiller Troubleshooting Checklist

Gathering a few details before making a service call can help speed diagnosis and reduce downtime.

✓ Record the alarm code
✓ Take a photo of the controller screen
✓ Note outdoor conditions and temperatures
✓ Check if condenser coils appear dirty
✓ Verify filters are installed correctly
✓ Look for visible oil residue around refrigerant components
✓ Document when the issue first started
✓ Check if the alarm has occurred before
✓ Avoid repeatedly resetting alarms without investigating the cause

The more information available before a service call, the faster technicians can often identify the root cause.

THE BOTTOM LINE

An estimated 75% of chiller failures are preventable, but this requires understanding the failure patterns. For example, compressor burnout is often the end result of ignoring low refrigerant alarms, which indicate a leak. Bearing failure can be traced back to missed oil analysis that would have detected contaminants or acid buildup. By performing specific, targeted maintenance, like regular leak checks, eddy current tube testing, and vibration and oil analysis, you can catch these issues early and prevent the vast majority of emergency repairs, downtime, and catastrophic failures.

The best technicians and facility operators don’t simply clear alarms. They ask why the alarm happened in the first place.

Because when it comes to commercial chillers, an alarm isn’t the problem. It’s the clue.

The real repair begins when someone takes the time to find the cause.

A Proactive Maintenance Checklist: Key Tasks to Help Prevent Failure

4-Point Checklist Top Technicians and Mechanical Contractors Should Never Miss

✓ Perform Annual Oil and Refrigerant Analysis: Lab analysis can detect moisture, acid, and metal particles that indicate internal wear long before a failure.
✓ Conduct Eddy Current Tube Testing: This non-destructive test identifies pitting, corrosion, and wall thinning in condenser and evaporator tubes, preventing unexpected leaks.
✓ Clean Heat Exchanger Tubes: For water-cooled chillers, annual tube brushing is essential to remove buildup that kills efficiency.
✓ Verify Sensor and Actuator Calibration: Ensure all safety and operating controls are reporting accurate data to the chiller’s controller.

Don’t Ignore the clues.

Every alarm tells a story. The key is having the experience to understand what it’s trying to tell you.

Whether you’re dealing with recurring alarms, unexpected shutdowns, or simply want confidence that your equipment is ready for the demands of summer, our technicians are here to help.

Let’s find the cause before it becomes the emergency.

Schedule Service | Request A Preventative Maintenance Inspection

Tulsa: (918) 585-9766
Oklahoma City: (405) 672-1100

Or request service online:

FAQ's About Chiller Lockouts and Alarms

Why does my chiller keep locking out?

A chiller lockout is typically a protective feature designed to prevent equipment damage when the system detects an unsafe operating condition. Common causes include refrigerant issues, airflow restrictions, electrical faults, sensor failures, or other mechanical problems. Simply resetting the lockout without identifying the root cause can lead to additional damage.

Should I reset a chiller lockout?

Resetting a lockout may temporarily restore operation, but it doesn’t address the reason the lockout occurred. If the underlying issue remains, the equipment may lock out again or continue operating under unsafe conditions. It’s best to identify and correct the cause before restarting the system.

What causes a low suction pressure fault on a chiller?

Low suction pressure faults can result from several issues, including low refrigerant charge, dirty condenser coils, restricted water flow, clogged strainers, or expansion valve problems. A complete diagnostic inspection is the best way to determine the exact cause.

Can dirty condenser coils cause chiller problems?

Yes. Dirty condenser coils restrict airflow, forcing the chiller to work harder and operate at higher temperatures. This can reduce efficiency, increase energy consumption, contribute to nuisance alarms, and place unnecessary stress on critical components.

How does preventative maintenance help prevent emergency repairs?

Routine preventative maintenance helps identify issues such as dirty coils, refrigerant leaks, worn electrical components, and restricted flow before they develop into larger problems. Addressing these items early can reduce downtime, improve reliability, and extend equipment life.

What should be checked before restarting a locked out chiller?

Before restarting a locked out chiller, the cause of the lockout should be investigated. A qualified technician should inspect the equipment, review alarm history, evaluate electrical components, verify refrigerant charge, inspect airflow and water flow, and confirm the system is safe to operate before returning it to service.

What causes inconsistent cooling in my building?

Inconsistent cooling or ‘hot spots’ are often early warning signs of a chiller problem. The issue could be a refrigerant leak that has reduced the system’s overall capacity, or sediment buildup in heat exchangers that is restricting water flow to certain parts of the building. It can also be caused by restricted airflow in the air handling units. It’s a clear indicator that the chiller is struggling to meet the building’s cooling demand and requires a diagnostic inspection.

This article was prepared by the engineering, service, and technical experts at Oklahoma Chiller, supporting commercial and industrial facilities across Oklahoma and surrounding states.